The idea with this special function is to use it together with a Widget in BZX21 called "Weight process". If this special function is not activated on the machine with the Widget, the Widget will not show any data. In BZX21 top right corner there is a menu, in there go to the option called "Edit Template". This is where all available Widgets are located, and can be added / removed.
With this special function activated it will be possible to do a weight control in the web solution. Contact Delacroys support for any additional help/information regarding the web solution. For this to work as intended some changes has to be made.
Via "Client" -> "Administration" -> "System settings" -> "Basic data"- > "Machines" -> "Machine parameters 6"you have to add values from process values on the selected machine.
Via "Client" -> "Administration" -> "System settings" -> "Parts" -> "Enter parts" -> "Parts 2" -> "Parts information 4" the parts value will be set.
Via "Client" -> "Administration" -> "System settings" -> "Basic data" -> "General company settings" the system will collect the lower- and upper values from selected machine. As well as the total amount of units that will be placed for the weight control. In our example below the value is 10, the number of units will correspond to that value, so it will be 10 units.
Machine parameters
6
Parts 2 - Parts information
4
General company settings
When the system performs a weight control the calculation is as follows: parts value*limit value, part_info4*sf325_value, see an example below:
value*sf325_weight_out_of_bounds_upper -> 2*4,0 =
8
value*sf325_weight_out_of_bounds_lower -> 2*0,3 =
0,6
value*sf325_weight_tolerance_upper -> 2*3,1 =
6,2
value*sf325_weight_tolerance_lower -> 2*0,9 )
1,8
sf325_total_quantity -> 10